在64位的win7上安装64位的Informatica后,建立domain、PowerCenter存储库服务都没有问题,但是在建立PowerCenter集成服务时,出现了如下错误:
进程服务 [integration] output error [ERROR: Unexpected condition at file:[..\utils\pmmetrics.cpp] line:[2118]. Application terminating. Contact Informatica Technical Support for assistance.].
网上找到了解决方法地址:http://opacki.eu/autoinstalator/joomla/component/content/article/48-informatica-powercenter-administration/75-pmmetricscpp-error
is the corruption of the performance counter setting.
The above message explains why Integration Service cannot start. To see the message, set node "error severity" attribute to "debug".To rebuild the performance counter setting from the system backup store just run the following commands (depending on your OS):
- On Windows Vista and Windows 7:lodctr /R
-
On Windows XP:lodctr /R:PerfStringBackup.INI
The command must be executed with administrative rights.
我的是win7,运行lodctr /R后,就可以正确建立集成服务了。
相关推荐
Informatica常见错误查询-中文
Informatica 数据集成管理解决方案.pdf
Informatica 性能调优
Informatica将大数据定义为大交易数据、大交互数据以及大数据处理的总称。摒弃将业务扩展到相邻技术(例如数据库...因此,凭借更广泛和统一的Informatica 9.5版,Informatica已经成为数据集成领域的一站式服务提供商。
Informatica PowerCenter数据集成平台介绍
如何在实际中应用ETL etl项目理论知识 在实际中应用etl的指导,企业信息资源整合集成的指导方案
Informatica服务器中断处理方案
Informatica提供市场上一流的数据集成平台。Informatica的任务?是满足的客户需要:一个能够从更多系统,在相比之下更短的时间内,集成更多数据的数据集成解决方案。 Informatica的数据集成平台经历过大约500,000个...
Informatica Platform适用于数据驱动企业的数据集成平台.pdf
凭借9.5版本,Informatica成为数据集成一站式服务提供商实用.pdf
为Informatica配置Email服务(Exchange),很详细
INFORMATICA 10.4.1官网版本
Informatica常见问题以及解答
INFORMATICA POWERCENTER 9.5.0服务器端安装步骤
1. 安装Powercenter 7.12,8.11客户端,知识库服务器及Informatica服务器软件; 需要指定注册码; 2. 在本机上建立供测试用的的Informatica Server; 7.12的Windows的一台机器上只能装一个这样的Server,建立时需要...
informatica后台数据库表整理,记录了部分数据库表名与关联关系
Informatica入门
Informatica PowerCenter标准版是一种单一且统一的企业数据集成平台,几乎可用于从任何业务系统获取、访问和集成任何格式的数据,并在整个企业中交付数据。此版本提供最高层次的可扩展性、安全性和可靠性。Power...