laosu
  • 浏览: 12811 次
  • 性别: Icon_minigender_1
  • 来自: 北京
社区版块
存档分类
最新评论

Informatica新建集成服务错误

 
阅读更多

        在64位的win7上安装64位的Informatica后,建立domain、PowerCenter存储库服务都没有问题,但是在建立PowerCenter集成服务时,出现了如下错误:

        进程服务 [integration] output error [ERROR: Unexpected condition at file:[..\utils\pmmetrics.cpp] line:[2118]. Application terminating. Contact Informatica Technical Support for assistance.].

         网上找到了解决方法地址:http://opacki.eu/autoinstalator/joomla/component/content/article/48-informatica-powercenter-administration/75-pmmetricscpp-error

        is the corruption of the performance counter setting.

        The above message explains why Integration Service cannot start. To see the message, set node "error severity" attribute to "debug".To rebuild the performance counter setting from the system backup store just run the following commands (depending on your OS):

 

  • On Windows Vista and Windows 7:lodctr /R

 

  • On Windows XP:lodctr /R:PerfStringBackup.INI

 

         The command must be executed with administrative rights.

 

         我的是win7,运行lodctr /R后,就可以正确建立集成服务了。